AIR VELOCITY PROBE - IC-FLUKE-975VP

ORDER ME IN
Product code: IC-FLUKE-975VP

Backorder Now, once ordered your item will dispatch before the 29th of April 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).

The Fluke 975VP Velocity Probe allows for one touch air flow and velocity measurements. The 975 Velocity Probe extends the reach of the Fluke 975 and is easy to use. Reach into small areas for precise readings. Velocity (FPM) 50 to 3000 Velocity (MPS) 0.025 to 15. Use with the 975 to measure air velocity from 50 to 3000 fpm.
Regular price $1,312.00 AUD + GST
$1,443.20 AUD Inc. GST

Features:

Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
One-touch air flow and velocity with available probe*
Wet bulb and dew point temperature
% of outside air calculation
CO2 and CO field calibration feature
Self-test function at startup
Auto-backlight
Automatically compensates for barometric pressure changes
Min/Max/Average on all measured and calculated readings
Multi-language user interface
Metric or standard units
Audible and visual threshold alarms
Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
Keypad lock for security
Included FlukeView Forms® software

Specifications



Temperature range: -20 °C to 50 °C (-5 °F to 122 °F)
Temperature display resolution: 0.1 °C (0.1 °F)
Temperature accuracy: ± 0.9 °C/± 1.62°F from 40 °C to 60 °C/± 0.5 °C/± 1.00°F from 5 °C to 40 °C/± 1.1 °C/± 1.98 °F from -20 °C to 5 °C

Relative humidity range: 10 % to 90 % RH, non-condensing
Relative humidity display resolution: 1%
Relative humidity accuracy: ± 2 % RH (10 % RH to 90 % RH)

Air velocity range: 50.0 fpm to 3000 fpm/0.25 m/sec to 15 m/sec
Air velocity display resolution: 1 fpm (0.005m/sec)
Air velocity accuracy: ±4 % or 4 fpm/±4 % or 0.02 m/sec* whichever is greater

C0 range: 0 to 500 ppm
CO display resolution: 1 ppm
CO accuracy: ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH
CO2 range: 0 to 5000 ppm
CO2 Display Resolution: 1 ppm
CO2 accuracy: Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au