- Enables high voltage measurement up to CAT III 2000 V
- Safely measure solar installations like the mega-solar without interrupting the grid by simply connecting the DC High Voltage Probe P2000 to compatible Hioki clamp meters and digital multimeters (DMMs)
- Boost work efficiency in the field by letting you directly transfer measurement data to (i.e., enter measured values directly into) templates created as Excel.
- Automatic hold function
- Can simultaneously measure inrush current in RMS as well as maximum crest values at motor startup and for welding currents.
- Also automatically detect the duration of the inrush current (which can range from several dozen milliseconds to several hundred milliseconds) and measure the current during that interval, enabling them to yield more accurate measurements than standard clamp-on meters whose measurement interval is fixed to 100 ms
- DC Current range: 20.00 A/600.0 A, Basic accuracy: +/- 1.3% rdg. 0.08 A (20 A range)
- AC Current range: 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45 to 66 Hz: +/- 1.3% rdg. +/- 0.08 A (at 20 A)
- Crest factor: 20.00 A range: 7.5 / 600.0 A range: 3 or less
- DC+AC Current range: 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45 to 66 Hz: +/- 1.3% rdg. +/- 0.13 A (at 20 A)
- DC Voltage range: 600.0 V to 1000 V (When using P2000: 600.0 V to 2000 V)
- AC Voltage range: 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 to 66 Hz: +/- 0.9% rdg. +/- 0.003 V (at 6 V)
- DC+AC Voltage range: 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 to 66 Hz: +/- 1.0% rdg. +/- 0.013 V (at 6 V)
- Resistance range: 600.0 ohms to 6.000 milliohms, 5 ranges, Basic accuracy: +/- 0.7% rdg. +/- 0.5 ohms (at 600 ohms)
- Capacitance range: 1.000 uF to 1000 uF, 4 ranges, Basic accuracy: +/- 1.9% rdg. +/- 0.005 uF (at 1 uF)
- Frequency range: 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: +/- 0.1% rdg. +/- 0.003 Hz (at 9.999 Hz)
- Temperature (K): -40.0 to 400.0 C, add temperature probe accuracy to basic accuracy of +/- 0.5% rdg. +/- 3.0 C
- Voltage detection Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
- Other functions: DC power, Continuity check, Diode check, Automatic AC/DC detection, Pass/fail judgement function of DC A and DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment
- Dustproof, waterproof: IP54 (Storage or measurement of current of an insulated conductor)
- Power supply: LR03 Alkaline battery x2. Continuous use: 40 hr (without Z3210 installed), 20 hr. (with Z3210 installed and using wireless communications). Other conditions: 10 A AC measurement, backlight off, 23C reference value
- Core jaw diameter: 33 mm diameter, Jaw dimension: 69 x 14 mm
- Dimensions and mass: 65 x 215 x 35 mm, 340 g
- Included accessories: Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery x2, Instruction Manual x2, Operating Precautions x1