DT4252 Digital Multimeter

ORDER ME IN
Product code: DT4252

Backorder Now, once ordered your item will dispatch before the 15th of May 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).

The DT4252 is a digital multimeter designed specifically for general purpose testing, with +/- 0.3% DC V accuracy, direct current input and wide 40 Hz to 1 kHz bandwidth.

-+/- 0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics.

-Measure up to 10A with direct input.

-Dual display lets you check voltage and frequency simultaneously.

Regular price $419.40 AUD + GST
$461.34 AUD Inc. GST
The DT4252, which is part of Hiokis DT4250 series of standard digital multimeters, packs a broad range of measurement capability into a single package.
Features:
- Accurately measure the fundamental wave alone by eliminating harmonic components with the DMMs low-pass filter function.
- True RMS measurement for accurate measurement of even distorted current waveforms
- To ensure operators ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.

Specifications

- DC Voltage range: 600.0 mV to 1000 V, 5 ranges. Basic accuracy: +/- 0.3 % rdg. +/- 5 dgt.
- AC Voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
- Basic accuracy: 40 to 500 Hz : +/- 0.9 % rdg. +/- 3 dgt. (True RMS, crest factor 3)
- Resistance range: 600.0 ohms to 60.00 milliohms, 6 ranges, Basic accuracy: +/- 0.7 % rdg. +/- 5 dgt.
- DC Current range: 6.000 A / 10.00 A, 2 ranges, Basic accuracy: +/- 0.9 % rdg. +/- 5 dgt.
- AC Current range: 6.000 A / 10.00 A, 2 ranges, Basic accuracy 40 to 500 Hz : +/- 1.4 % rdg. +/- 3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz)
- Capacitance range: 1.000 uF to 10.00 mF, 5 ranges, Basic accuracy: +/- 1.9 % rdg. +/- 5 dgt.
- Frequency range: AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges, 99.99 kHz (only for AC V). Basic accuracy: +/- 0.1 % rdg. +/- 1 dgt.
- Continuity check Continuity threshold: [ON]: 25 ohms or less (Indicate buzzer sound, red LED), [OFF]: 245 ohms or more. Response time: 0.5 ms or more
- Diode test: Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
- Other functions: Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
- Display: Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph
- Display: refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
- Power supply: LR03 alkaline batteries x4, Continuous use: 130 hours (back light OFF)
- Dimensions and mass: 84 x 174 x 52 mm, 390 g
- Accessories: Test lead L9207-10 x1, Holster x1, Instruction manual x1, LR03 alkaline battery x4

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au