The DT4253, which is part of Hiokis DT4250 series of standard digital multimeters, is ideal for measuring instrumentation, air conditioning equipment, and gas-burning devices.
- 600.00 uA range for measuring very low currents used by gas-burning devices
- The instrument can convert and display instrumentation signals of 4 to 20 mA or 0 to 20 mA representing properties such as temperature, pressure, and flow rate from a transducer or other device that converts sensor data into an electrical signal.
- Mistakenly measuring voltage using the current range may lead to a short-circuit. The DT4253 eliminates the root cause of such accidents by providing clamp-on sensor based current measurement functionality instead of using conventional probes.
- Measure output voltage on the secondary sides of inverters by eliminating harmonic components
- To ensure operators ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.
- DC Voltage range: 600.0 mV to 1000 V, 5 ranges, Basic accuracy: +/- 0.3 % rdg. +/- 5 dgt.
- AC Voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz. Basic accuracy 40 to 500 Hz : +/- 0.9 % rdg. +/- 3 dgt. (True RMS, crest factor 3)
- AUTO AC/DCV: Yes
- Resistance range: 600.0 ohms to 60.00 milliohms, 6 ranges, Basic accuracy: +/- 0.7 % rdg. +/- 5 dgt.
- DC Current range: 60.00 uA to 60.00 mA, 4 ranges, Basic accuracy: +/- 0.8 % rdg. +/- 5 dgt.
- From 4 to 20mA Percentage conversion display: Yes
- AC Current range (use with Clamp on probes): 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 to 1 kHz: +/- 0.9 % rdg. +/- 3 dgt. (True RMS, crest factor 3)
- Temperature (thermocouples) K: -40.0 to 400.0 C , Add the Temperature probe accuracy to basic accuracy: +/- 0.5 % rdg. +/- 2 C
- Capacitance range: 1.000 uF to 10.00 mF, 5 ranges, Basic accuracy: +/- 1.9 % rdg. +/- 5 dgt.
- Frequency range: 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), Basic accuracy: +/- 0.1 % rdg. +/- 1 dgt.
- Continuity check: Continuity threshold [ON]: 25 ohms or less, [OFF]: 245 ohms or more, Response time: 0.5 ms or more
- Diode test: Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
- Other functions: Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option), 4 to 20 mA percentage conversion
- Display: Main and Sub displays: 4 digits LCD, max. 6000 digits, bar graph. Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
- Power supply: LR03 alkaline batteries x4, Continuous use: 130 hours (backlight OFF)
- Dimensions and mass: 84 x 174 x 52 mm, 390 g (13.8 oz) (including batteries and holster)
- Accessories: Test lead L9207-10 x1, Holster x1, Instruction manual x1, LR03 alkaline battery x4