Head Mount Transmitter - RTD+Thermocouple Input, 4-20mA Output - XU2HI

ORDER ME IN
Product code: XU2HI-Intech

Backorder Now, once ordered your item will dispatch before the 03rd of May 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).

Suitable for head mounting on RTD and Thermocouple Temperature Sensors to convert the signal to 4-20mA (Loop Powered, This model Features a Zero trim pot for in field calibration and is also Isolated.
Regular price $219.00 AUD + GST
$240.90 AUD Inc. GST

Suitable for head mounting on RTD and Thermocouple Temperature Sensors to convert the signal to 4-20mA (Loop Powered, This model Features a Zero trim pot for in field calibration and is also Isolated.

USB Programmable RTD or Thermocouple Temperature Input.
Standard = RTD Pt100, 0~100C Input; Upscale; 4~20mA Output (Loop Powered).
Input to Output Isolation 3750Vac.
Heartbeat Status LED.
Zero Adjust pot.
Case Temperature range -20C to +85C.

Features:
Programmable via USB (requires the XU-USB programming key)
No power supply or calibration required during programming
Temperature Input Types:
- RTD Pt100 and Pt1000
- Thermocouple B, E, J, K, N, R, S, T.
- Output is Linear with Temperature.
High Accuracy 0.1%
Compact Industrial Head Mount Enclosure
Reverse Polarity Protection
Easy to Install
Low Cost

Specifications


Output 2 wire 4~20mA / or 20~4mA - Loop Powered.
Power Supply 9.5~36Vdc.
Supply Voltage Sensitivity <0.005%/V FSO.
Output Load Resistance 700 @ 24Vdc. (50/V Above 9.5Vdc.)
Maximum Output Current Limited to <28mA.
EMC Emissions Compliance EN 61326
EMC Immunity Compliance EN 61326
Safety Compliance EN 61010-1
Accurate to <0.03% FSO Typical.
Linearity & Repeatability <0.02% FSO Typical. (Unless Individual Specifications State Otherwise)
Ambient Drift <0.003%/C FSO Typical.
Noise Immunity 125dB CMRR Average. (2.0k Vdc Limit.)
R.F. Immunity <1% Effect FSO Typical.
Signal Isolation Voltage Between Input and Output 3750Vac for 1 min. (Excluding XU2HN)
Response Time 400msec Typical. (From 10 to 90% 300msec Typical.)
Sensor Fail Low 3.8mA, High 21mA
Startup Time 3 seconds, 3.7mA output
Output calibrate via Pot 0.5mA Zero offset adjust. (Excluding XU2HN)
Operating Temperature -20~85C (XU2HN: -20~55C)
Storage Temperature -20~100C
Operating Humidity 5~85%RH Max. Non-Condensing.
Mounting 35mm Symmetrical Mounting Rail. In Head mount for XU2HI & XU2HN

Dimensions:
Height: 44mm
Width: 44mm


The XU2HI can be easily programmed using the XU-USB programming key and the free XU programming software.





Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au