The ALTA Wireless Accelerometer - G-Force Max/Avg sensor measures the maximum and average g-force values along X, Y and Z axes. A heartbeat can be set to determine how long the sensor will accumulate data for before reporting in. Custom Delta values allow for the user to set thresholds which, when exceeded, will trigger the sensor to report in immediately. Configurable data rates allow for more samples to be collected for every measurement with higher data rates resulting in faster reaction time.
The data reported is useful for tracking periodic motion and event detection. There are six operating modes, 2 G, 4 G, or 8G each with an additional mode which employ a High Pass Filter. The data displayed is the g-force on each axis, e.g. ?> X: 0.001 Y: 0.031 Z: 1.01. A Re-arm time can be configured such that the sensor will not trigger too quickly after being triggered once.
ALTA sensors offer 3 to 4 times the range of standard sensor platforms, extending non-line-of-sight reach to an exceptional 1,200+ feet through walls (12-14 walls typical). Using Frequency-hopping Spread Spectrum (FHSS) also allows ALTA sensors to have better interference immunity from other wireless devices.
Superior power management provides ALTA sensors with almost twice the battery life of Monnit's standard wireless sensors. AA sensors typically last up to 12+ years. Integrated on-board data storage allows ALTA sensors to store data messages if communication to a wireless gateway is disrupted (power outage, Internet outage, or out of range). Messages that can't be delivered will be time-stamped and stored in memory (up to the last 512 messages) until communication with the gateway is restored, at which point the messages will all be transmitted.
Over-the-air updates allow ALTA products to be updated remotely if new fixes or features become available.
Specifications
- Sensitivity: 4096 count/g
- Minimum G Force to Turn On/Wake Up: 0.050 g - 0.100 g
- Current Consumption: 6 Hz - 32.4 uA: around 4 years lifetime at two hour heartbeat. 12 Hz - 36.2 uA: around 4 years lifetime at two hour heartbeat. 50 Hz - 66.5 uA: around 2 years lifetime at two hour heartbeat. 100 Hz - 125.6 uA: around 1 year lifetime at two hour heartbeat.
- Sensitivity Range: 2 G, 4 G, 8 G
- Measurement Accuracy: 2.5 % (force: X, Y, Z)
- Minimum G Force to Turn On/Wake Up: 0.050 to 0.100 g
- Data Rate: 6 Hz, 12 Hz, 50 Hz, 100 Hz
- Dimension: 4.375 in x 2.470 in x 1.12 in
- Supply Voltage: 2.0 - 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply)
- Battery Life: At 1 hour heartbeat setting, included AA batteries will typically last 6-8 Years.
- Max Operating Temperature Using AA Alkaline: -18 C to 55 C (0 F to 130 F)
- Max Operating Temperature Using AA Lithium: -40 C to 60 C (-40 F to 140 F)
- Optimal Battery Operating Temperature: 10 C to 50 C (50 F to 122 F)
- Enclosure Material: ABS