The ALTA wireless PM2.5 sensor measures PM1, PM2.5 and PM10 concentrations in the air and transmits the measurement to iMonnit. The PM2.5 sensor works by turning on a small fan at the beginning of a measurement cycle to bring in a volume of ambient air and measuring the particulate matter (PM) content of that sample volume. The sensor measures PM content using a laser that scatters based on the number and size of particles suspended in the air. It is important to keep the inlet ports of the sensor clear to ensure proper readings.
ALTA sensors offer 3 to 4 times the range of standard sensor platforms, extending non-line-of-sight reach to an exceptional 1,200+ feet through walls (12-14 walls typical). Using Frequency-hopping Spread Spectrum (FHSS) also allows ALTA sensors to have better interference immunity from other wireless devices. Superior power management provides ALTA sensors with almost twice the battery life of Monnit's standard wireless sensors. Monnit's AA sensors have a battery life that typically lasts 10+ years.
ALTA products employ Monnit's new Encrypt-RF Security (256-bit Diffie Hellman key exchange and AES-128 CBC encryption for all sensor data messages), so security is maintained at all communication points from sensor to gateway, gateway to software, then back again.
Integrated on-board data storage allows ALTA sensors to store data messages if communication to a wireless gateway is disrupted (power outage, Internet outage, or out of range). Messages that can't be delivered will be time-stamped and stored in memory (up to the last 512 messages) until communication with the gateway is restored, at which point the messages will all be transmitted.Over-the-air updates allow ALTA products to be updated remotely if new fixes or features become available.
The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase).
Applications:
- Building/Room Air Quality
- Pollution Sensing
- Mines and Quarries
- Cement Factories
- Construction/Demolition Sites
- Petrochemicals
- Agricultural/Waste
- Many additional applications
Specifications
- Measurement Sensitivity (PM1): 0.3 to 1.0 um
- Measurement Sensitivity (PM2.5): 1.0 to 2.5 um
- Measurement Sensitivity (PM10): 2.5 to 10 um
- Counting Efficiency: 50% at 0.3 um, 98% at >= 0.5 um
- Effective Range: 0 to 500 ug/m^3
- Maximum Range: 0 to 1000 ug/m^3
- Maximum Consistency Error: +/- 10% at 100 to 500 g/m^3; +/- 10 ug/m^3 at 0 to 100 ug/m^3
- Response Time: around 10 Seconds
- Active Current: around 180 mA at 3.3 battery voltage, around 0.6 W overall
- Operating Temperature: -10 C to 60 C
- Operating Humidity Range: 0 to 99%
- Mean Time to Failure: >= 3 Years
- Battery Type: 2 Replaceable AA 1.5 V Batteries
- Dimension: 4.375 in x 2.470 in x 1.12 in
- Supply Voltage: 2.0 - 3.8 V (2 x AA 1.5V Batteries or Optional Power Supply)
- Battery Life: At 1 hour heartbeat setting, included AA batteries will typically last 6-8 Years
- Max Operating Temperature Using AA Alkaline: -18 C to 55 C (0 F to 130 F)
- Max Operating Temperature Using AA Lithium: -40 C to 60 C (-40 F to 140 F)
- Optimal Battery Operating Temperature: +10 C to +50 C (+50 F to +122 F)
- Enclosure Material: ABS