AIRMETER WITH VELOCITY PROBE - IC-FLUKE-975V

DISCONTINUED
Product code: IC-FLUKE-975V

Unfortunately, the FLUKE-975V has been discontinued, check out our other Air Quality Meters for more alternatives.

The Fluke 975V AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. The Fluke 975 measures temperature, Velocity, Humidity, CO, and CO2.
Unfortunately, the FLUKE-975V has been discontinued, check out our other Air Quality Meters for more alternatives.

Features:

Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
One-touch air flow and velocity with available probe
Wet bulb and dew point temperature
% of outside air calculation
CO2 and CO field calibration feature
Self-test function at startup
Auto-backlight
Automatically compensates for barometric pressure changes
Min/Max/Average on all measured and calculated readings
Multi-language user interface
Metric or standard units
Audible and visual threshold alarms
Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
Keypad lock for security
Included FlukeView Forms software

Specifications



Temperature

Range: -20 C to 50 C (-5 F to 122 F)
Display resolution: 0.1 C (0.1 F)
Accuracy: 0.9 C/ 1.62F from 40 C to 60 C/ 0.5 C/ 1.00F from 5 C to 40 C/ 1.1 C/ 1.98 F from -20 C to 5 C

Relative humidity

Range: 10 % to 90 % RH, non-condensing
Display Resolution: 1%
Accuracy: 2 % RH (10 % RH to 90 % RH)

Air velocity

Range: 50.0 fpm to 3000 fpm/0.25 m/sec to 15 m/sec
Display Resolution: 1 fpm (0.005m/sec)
Accuracy: 4 % or 4 fpm/4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm.

C0

Range: 0 to 500 ppm
Display Resolution: 1 ppm
Accuracy: 5 % or 3 ppm, whichever is greater, @ 20 C and 50 % RH

C02

Range: 0 to 5000 ppm
Display Resolution: 1 ppm
Accuracy: Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm

Dew point temperature

Range: -44 C to 50 C, (-47 F to 122 F)
Display Resolution: 0.1 C (0.1 F)
Accuracy: 1 C when temp: -20 C to 50 C RH: 40 % to 90 %/ 2 C when temp: -20 C to 50 C RH: 20 % to 40 %/ 4 C when RH: 10 % to 20 %

Wet bulb temperature

Range: -16 C to 50 C, (3 F to 122 F)
Display Resolution: 0.1 C, (0.1 F)
Accuracy: 1.2 C when RH: 20 % to 90 % temp: -20 C to 60 C/ 2.1 C when RH: 10 % to 20 %

Volume flow rate (in a duct)

Range: 0 to 3,965 M3/m, (0 to 140,000 cfm)
Display Resolution: 0.001 M3/min, (1 cfm)
Accuracy: N/A: The volume flow calculation will be a simple average of the data points times the duct area

% outside air (based on temperature)

Range: 0 to 100%
Display Resolution: 0.1

% outside air (based on CO2)

Range: 0 to 100 %
Display Resolution: 0.1 % N/A


Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au