UX120-014M Details:
Broad range (-260 to 182C)
Easy-to view LCD display confirms logger operation and battery status
Near real-time readout of current temperatures as well as minimum, maximum, average and standard deviation statistics
Large memory capacity capable of storing 1.9 million measurements
On-screen alarms notify you if temperatures exceed high or low thresholds
Start, stop, and restart push buttons
User upgradeable firmware
Can accept up to four J, K, T, E, R, S, B, or N type probes
Specifications
Specifications:
Thermocouple |
|||
Type |
Range |
Accuracy |
Resolution |
J |
-210 to 760 C (-346 to 1,400 F) |
+/- 0.6 C (+/- 1.08 F) thermocouple probe accuracy |
0.03 C (0.06 F) |
K |
-260 to 1,370 C (-436 to 2,498 F) |
+/- 0.7 C (+/- 1.26 F) thermocouple probe accuracy |
0.04 C (0.07 F) |
T |
-260 to 400 C (-436 to 752 F) |
+/- 0.6 C (+/- 1.08 F) thermocouple probe accuracy |
0.02 C (0.03 F) |
E
|
-260 to 950 C (-436 to 1,742 F) |
+/- 0.6 C (+/- 1.08 F) thermocouple probe accuracy |
0.03 C at (0.05 F) |
R |
-50 to 1,550 C (-58 to 2,822 F) |
+/- 2.2 C (+/- 3.96 F) thermocouple probe accuracy |
0.08 C (0.15 F) |
S |
-50 to 1,720 C (-58 to 3,128 F) |
+/- 2.2 C (+/- 3.96 F) thermocouple probe accuracy |
0.08 C (0.15 F) |
B |
550 to 1,820 C (1,022 to 3,308 F) |
+/- 2.5 C (+/- 4.5 F) thermocouple probe accuracy |
0.1 C (0.18F) |
N |
-260 to 1,300 C (-436 to 2,372 F) |
+/- 1.0 C (+/- 1.8F) thermocouple probe accuracy |
0.06 C (0.11 F) |
Internal 10K Thermistor (Temperature): |
||
Range Logging |
-20 to 70 C (-4 to 158 F) |
![]() |
Accuracy |
+/- 0.21 C from 0 to 50 C (0.38 F from 32 to 122 F), see Plot A |
|
Resolution |
0.024 C at 25 C (0.04 F at 77 F); see Plot A |
|
Drift |
<0.1 C (0.18 F) per year |
Logger Operating Range |
Logging: -20 to 70 C (-4 to 158 F); 0 to 95% RH (non-condensing); logger accuracy from 0 to 50 C (32 to 122 F) Launch/Readout: 0 to 50 C (32 to 122 F) per USB specification |
Logging Rate |
1 second to 18 hours, 12 minutes, 15 seconds |
Logging Modes |
Normal, Burst or Statistics |
Memory Modes |
Wrap when full or stop when full |
Time Accuracy |
1 minute per month at 25 C (77 F), see Plot B |
Start Modes |
Immediately, Push Button, Date & Time or Next Interval |
Stop Modes |
When Memory Full, Push Button, or Date & Time |
Restart Mode |
Push Button |
Memory |
4 MB (1.9 million measurements, maximum) |
Download Type |
USB 2.0 interface |
Full Memory Download Time |
Approximately 1.5 minutes |
LCD |
LCD is visible from: 0 to 50 C (32 to 122 F); the LCD may react slowly or go blank in temperatures outside this range. |
IP Rating |
IP50 |

Battery Type: Two AAA 1.5V alkaline batteries, user replaceable
10.8 x 5.41 x 2.54 cm
Weight: 30 g
Warranty
- 1 Year Manufacturer Warranty + Additional 1 Year Instrument Choice Warranty
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au