Digital pH,EC,DO Portable Meter with HI829113 pH Electrode - IC-HI98199
Backorder Now, once ordered your item will dispatch before the 21st of May 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).
The HI98199 is a rugged, portable multiparameter meter with a single digital probe input that allows it to use either a pH, conductivity or dissolved oxygen probe.
- - Can measure up to 10 water quality parameters with 5 being measured by sensors and the other 5 by calculation (i.e. EC to TDS).
- - Complies to IP67 standards,
- - Supplied with a pH/temperature probe. Other compatible probes for dissolved oxygen, conductivity, are sold separately.
$1,431.63 AUD Inc. GST




Specifications
pH Accuracy
|
+/- 0.02 pH
|
pH Calibration
|
automatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
|
pH Temperature Compensation
|
yes
|
mV Range
|
+/- 600.0 mV
|
mV Resolution
|
0.1 mV
|
mV Accuracy
|
+/- 0.5 mV
|
EC Range
|
0 to 200 mS/cm
|
EC Resolution
|
1 uS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
|
EC Accuracy
|
+/- 1.5% of reading or +/- 2 uS/cm whichever is greater
|
EC Calibration
|
automatic single-point, with six standard solutions (84 S/cm, 1413 S/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
|
TDS Range
|
0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor)
|
TDS Resolution
|
1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L)
|
TDS Accuracy
|
+/- 1% of reading or +/- 1 ppm (mg/L) whichever is greater
|
TDS Calibration
|
based on conductivity calibration
|
EC/TDS Temperature Compensation
|
yes
|
Temperature Correction Coefficient
|
0.00 to 6.00 %/C
|
EC to TDS Conversion Factor
|
0.00 to 1.00
|
Reference Temperature
|
25 C or 20 C
|
Cell Type
|
four ring
|
EC/TDS Multi-range Measurement Modes
|
yes
|
Salinity (PSU) Range
|
0.00 to 70.00 PSU
|
Salinity (PSU) Resolution
|
0.01 PSU
|
Salinity (PSU) Accuracy
|
+/- 2% of reading or +/- 0.01 PSU whichever is greater
|
Salinity (PSU) Calibration
|
based on conductivity calibration
|
Salinity (Seawater Sigma) Range
|
0.0 to 50.0 t, 0, 15
|
Salinity (Seawater Sigma) Resolution
|
0.1 t, 0, 15
|
Salinity (Seawater Sigma) Accuracy
|
+/- 1 t, 0, 15
|
Salinity (Seawater Sigma) Calibration
|
based on conductivity calibration
|
Resistivity Range
|
0 to 999999 cm; 0 to 1000.0 kcm; 0 to 1.0000 Mcm
|
Resistivity Resolution
|
1 cm; 0.1 kcm; 0.0001 Mcm
|
Resistivity Calibration
|
based on conductivity calibration
|
Dissolved Oxygen Measurement Type
|
galvanic
|
Dissolved Oxygen Range
|
0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
|
Dissolved Oxygen Resolution
|
0.1%; 0.01 ppm (mg/L)
|
Dissolved Oxygen Accuracy
|
0.0 to 300.0%
|
Dissolved Oxygen Calibration
|
automatic one or two points at 0, 100% or one custom point
|
Dissolved Oxygen Temperature Compensation
|
yes
|
Barometric Pressure Compensation
|
yes
|
Salinity Compensation
|
yes
|
Temperature Range
|
-5.00 to 55.00 C; 23.00 to 131.00 Output!B1F; 268.15 to 328.15 K
|
Temperature Resolution
|
0.01 C; 0.01 F; 0.01 K
|
Temperature Accuracy
|
0.15 C; 0.27 F; 0.15 K
|
Temperature Calibration
|
automatic at one custom point
|
Temperature Compensation
|
automatic from -5 to 55 C (23 to 131 F)
|
Logging Type
|
continuous logging or log-on-demand
|
Logging Memory
|
45000 records
|
Logging Interval
|
one second to three hours
|
Connectivity
|
via USB-C with Hanna software
|
Automatic Shut-Off
|
Not used (disabled), 5, 10, 15, 20, 30, 60 minutes
|
GLP
|
yes
|
Calibration Timeout Reminder
|
yes
|
Display
|
dot matrix
|
Battery Type/Life
|
1.5V AA batteries (4) / approximately 400 hours of continuous use without backlight (50 hours with backlight)
|
IP Protection
|
IP67
|
Environment
|
0 to 50 C (32 to 122 F); RH 100%
|
Dimensions
|
185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4)
|
Weight
|
400 g (14.2 oz.)
|
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au