EC 2000-S Features:
- Up to 2.000 S/cm conductivity range
- Adjustable reference temperature: 15 to 30 C
- Adjustable temperature coefficient: 0.00 to 10.00 % per C
- Accepts 0.0700 to 13.000 cell constant
- Allows auto and manual conductivity calibrations
- Up to 5 conductivity calibration points
- Auto ranging S/cm and S/m conductivity units
- 0.01 mg/L to 100 g/L TDS range
- Pre-programmed TDS curves: Linear (0.40 to 1.00 TDS factor), EN27888, 442, & NaCl
- 0.0 to 100.0 ppt and 0.00 to 10.00 % salinity ranges
- Pre-programmed salinity curves: NaCl and seawater
- -30.0 to 130.0 C temperature range with calibration option
- Auto stable, auto hold, and real time measurement modes
- Electrode status, temperature, and reading stability indicators viewable at a glance
- Large memory accepting up to 2000 data sets with date/time stamp
- Auto data log function with adjustable time interval
- Real time clock facilitating time-dependent functions
- Adjustable auto shut-off time up to 30 mins.
- Password protected set-up mode for security
- Software upgrade capability
- PC communication via USB cable and complimentary data acquisition software
- Printer communication via RS232 cable
- 5 inch Digital, custom LCD display with backlight
- Sleek design with easy-to-use interface and audible key sound feedback
- Small meter footprint with adjustable, integrated electrode stand
EC 2000-S Specifications
Conductivity:
- Ranges: 0.000 to 1.999 S/cm (k = 0.1); 2.00 to 19.99 S/cm (k = 0.1, 1); 20.0 to 199.9 S/cm (k = 0.1, 1, 10); 200 to 1999 S/cm (k = 0.1, 1, 10); 2.00 to 19.99 mS/cm (k = 0.1, 1, 10); 20.0 to 199.9 mS/cm (k = 1, 10); 0.200 to 2.000 S/cm (k = 10)
- Units: Auto ranging S/cm, S/m (S to mS)
- Resolution: 0.05% full scale
- Accuracy: +/- 0.6% full scale; +/- 1.5% full scale greater than 18.0 mS/cm
- Reference Temperature: 15.0 to 30.0 C (adjustable)
- Temperature Coefficient: 0.00 to 10.00 % per C (adjustable)
- Cell Constants: 0.0700 to 13.000 (adjustable)
- Calibration Points: Up to 4 (Auto) / Up to 5 (Manual)
Resistivity:
- Range: 0.000 ohm centimeter to 20.0 million ohms
- Resolution: 0.5% full scale
- Accuracy: +/- 0.6% full scale; +/- 1.5% full scale
TDS:
- Range: 0.01 to 9.99 mg/L (ppm); 10.0 to 99.9 mg/L (ppm); 100 to 999 mg/L (ppm); 1.00 to 9.99 g/L (ppt); 10.0 to 100 g/L (ppt)
- Resolution: 0.01, 0.1, 1 mg/L to g/L (ppm to ppt)
- Accuracy: +/- 0.1% full scale
- TDS Curves: EN27888, 442, NaCl, Linear (0.40 to 1.00)
Salinity:
- Range: 0.0 to 100.0 ppt / 0.00 to 10.00 %
- Resolution: 0.1 ppt / 0.01%
- Accuracy: +/- 0.2% full scale
- Salinity Curves: NaCl/Seawater
- Calibration Option: Yes
Temperature:
- Range: -30.0 to 130.0 C
- Resolution: 0.1 C
- Accuracy: +/- 0.5 C
- Calibration Option: Yes (+/- 10.0 C / in 0.1 C increments)
General:
- Memory: 2000
- Auto Data Log: Yes
- Real-time Clock: Yes
- Date & Time Stamp: Yes
- Measurement Modes: Auto Stable / Auto Hold / Real Time
- Auto Shut-Off: Yes (Programmable: up to 30 mins.)
- Electrode Status: On screen display
- Diagnostics: Yes
- Password Setting: Yes
- Software Upgrade: Yes
- PC / Printer Communication: Phono jack (USB / RS232C)
- Meter Inputs: BNC, phono, DC sockets
- Display: 5 inch Custom LCD with backlight and 320 segments
- Power Requirement: AC adaptor 100 to 240V, 50 to 60Hz
- Dimensions and Weight: 155(L) x 150(W) x 67(H) mm, 765g
9382-10D Specifications:
- Measurement Range: 1 uS/cm - 100 mS/cm; 0.1 mS/m - 10 S/m
- Temp. Range: 0 to 80 C
- Body: Titanium
- Cell Constant: 1 cm-1; 100 m-1
Kit includes:
- EC 2000 meter
- Electrode stand
- 9382-10D plastic-body, Titanium/Platinum black, conductivity cell, k=1.0
- 503-S (84 uS/cm, 1413 uS/cm, 12.88 mS/cm, 111.9 mS/cm - 250ml ea)