Fluke 1738 Advanced Power Logger - IC-FLUKE-1738/B
Unfortunately, the FLUKE-1738/B has been discontinued, check out our other Power Loggers for more options.


Features:
Automatically capture and log voltage, current, power, harmonics and associated power quality values.
Summarizes the most important power quality health parameters to provide fast insight into overall electrical system health, indicating whether more detailed analysis and reporting should be done.
Fluke Connect compatible: View data locally on the instrument or via Fluke Connect mobile app and desktop software.
Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream.
Measure all three phases and neutral using 4 flexible current probes
More than 20 separate logging sessions can be stored
Includes event waveform snapshot and high resolution RMS profile, along with date, timestamp and severity to help pinpoint potential root causes of power quality issues.
Colored touch-screen with optimized user-interface
Complete "in-the-field" setup through the front panel or Fluke Connect App
Energy Analyze Plus application software: Download and analyze every detail of energy consumption and power quality state of health with our automated reporting.
Fully integrated logging: Connect other Fluke Connect devices to the Fluke 1738 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter.
Specifications
Accuracy | ||||
Parameter | Range | Resolution | Intrinsic Accuracy at Reference Conditions
(% of Reading +% of Full Scale) |
|
Voltage |
1000 V |
0.1 V |
(0.2% + 0.01%) |
|
Current: Direct input |
i17xx-flex 1500 12" |
150 A |
0.1 A |
(1% + 0.02%) |
1500 A |
1 A |
|||
i17xx-flex 3000 24" |
300 A |
1 A |
(1% + 0.03%) |
|
3000 A |
10 A |
|||
i17xx-flex 6000 36" |
600 A |
1 A |
(1.5% + 0.03%) |
|
6000 A |
10 A |
|||
i40s-EL clamp |
4 A |
1 mA |
(0.7% + 0.02%) |
|
40 A |
10 mA |
|||
Frequency |
42.5 Hz to 69 Hz |
0.01 Hz |
(0.1%) |
|
Auxillary input |
10 V dc |
0.1 mV |
(0.2% + 0.02%) |
|
Voltage min/max |
1000 V |
0.1 V |
(1% + 0.1%) |
|
Current min/max |
Defined by accessory |
Defined by accessory |
(5% + 0.2%) |
|
THD on voltage |
1000% |
0.1% |
0.5 |
|
Voltage harmonics 2nd to 50th |
1000 V |
0.1 V |
10 V: 5% of reading |
|
< 10 V: 0.5V | ||||
Current harmonics 2nd to 50th |
Defined by accessory |
Defined by accessory |
3% of current range: 5% of reading |
|
< 3% of current range: 0.15% of range | ||||
Unbalance |
100% |
0.1% |
0.2 |
|
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au