Milesight AM319 - Indoor Air Quality 9 in 1 with Ozone LoRaWAN Sensor
Backorder Now, once ordered your item will dispatch before the 16th of May 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).
The AM319-915M-O3 is a compact indoor ambience monitoring sensor for measurement of Temperature, Humidity, PIR, Light, TVOC, Barometric Pressure, Carbon Dioxide (CO2), Particulate Matter (PM2.5 & PM10), formaldehyde and ozone.
- Recorded readings are displayed in real-time through a 4.2 inch E-ink screen.
- Sensor data is transmitted using LoRaWAN
- Manage all sensor data remotely and visually through the Cloud when used with Milesight's gateways
$615.01 AUD Inc. GST




Specifications
Frequency
|
CN470/RU864/IN865/EU868/US915/AU915/KR920/AS923-1&2&3&4
|
Tx Power
|
16dBm(868MHz)/22dBm(915MHz)/19dBm(470MHz)
|
Sensitivity
|
-137dBm at 300bps
|
Work Mode
|
OTAA/ABP Class A
|
Temperature
|
Sensor
|
Operating Principle
|
Digital CMOSens technology (MEMS)
|
Range
|
-20 to 60 C
|
Accuracy
|
+/- 0.2 C
|
Resolution
|
0.1 C
|
Humidity
|
Sensor
|
Operating Principle
|
Digital CMOSens technology (MEMS)
|
Range
|
0% - 100% RH
|
Accuracy
|
+/- 2% RH
|
"Resolution "
|
0.5% RH
|
Motion
|
Sensor
|
Operating Principle
|
Passive infrared (PIR)
|
"Detection Range "
|
80 degrees Horizontal, 55 degrees Vertical, 5m
|
Status
|
Vacant/Occupied
|
Light
|
Sensor
|
Operating Principle
|
Photodiode
|
Range
|
0-60000 Lux (Determine as 6 levels, 0-5)
|
TVOC
|
Sensor
|
Operating Principle
|
MOX (MEMS)
|
Range
|
1.00 - 5.00 (IAQ Rating)
|
Accuracy
|
+/- 1
|
Resolution
|
0.01
|
Barometric Pressure
|
Sensor
|
Operating Principle
|
Piezoresistive absolute pressure sensor (MEMS)
|
Range
|
260 - 1260 hPa
|
Accuracy
|
+/- 0.5 hPa
|
Resolution
|
0.1 hPa
|
Carbon Dioxide
|
Body cell
|
Operating Principle
|
Nondispersive Infrared (NDIR)
|
Range
|
400 - 5000 ppm
|
Accuracy
|
+/- (30 ppm + 3 % of reading) (0 to +50 C)
|
Resolution
|
1 ppm
|
PM2.5 & PM10
|
Body cell
|
Operating Principle
|
Laser Scattering
|
Range
|
0 - 1000 ug/m3
|
Accuracy
|
0-100 (+/- 10ug/m3), 100-1000(+/- 10%); (-10 C to +60 C)
|
Resolution
|
1 ug/m3
|
Formaldehyde (HCHO)2
|
Body cell
|
Operating Princicple
|
Electrochemical
|
Range
|
0 - 1.25 mg/m3 (760 mmHg and 20 C, 1 ppm = 1.25 mg/m3)
|
Accuracy
|
+/- 10 %
|
Resolution
|
0.01 mg/m3
|
"Working Life "
|
6 Years
|
Ozone
|
Body cell
|
Range
|
0 - 10 ppm
|
Accuracy
|
+/- 5 %FS
|
Resolution
|
0.01 ppm
|
"Working Life "
|
2 Years
|
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au