Whether it be to verify questions of liability, detect damage early or to optimise packaging: The MSR175 data logger accurately records critical transport events such as shocks, jolts or fluctuations in temperature, pressure or humidity and provides clarity with objective measured data.
The two digital 3-axis-acceleration sensors (+/- 15 g and +/- 200 g) integrated in the MSR175 record shocks at a measurement frequency of up to 6400/s. The storage capacity of over 2 million measured values is sufficient to record at least 1,000 shocks (230 mAh Li-Po battery).
In addition, this version of the transportation data logger measures and records temperature profiles from -20 to +65 C. Further type variants of the MSR175 are available with internal humidity, air pressure and light sensors.
The software package for the MSR175 includes 3 programs: MSR175 Dashboard, MSR ReportGenerator and MSR ShockViewer. The MSR Dashboard allows you to configure the logger with just a few mouse clicks. The data recorded can be quickly transferred to a computer via the USB port. A single click on the MSR ReportGenerator is sufficient to call up a compact report. For a detailed measured data analysis, the MSR ShockViewer, which is integrated in the MSR175 software package as a free basic version, is at your disposal.
Features:
- High-speed shock logger with 2 internal acceleration sensors
- 3 shock measurement modes: either +/- 200 g at 6400 Hz or +/- 200 g at 3200 Hz or +/- 15 g at 1600 Hz
- Sensors for temperature, humidity, pressure and light
- Installed memory is capable of storing over 2 million measured values
- Setting of limit values
- Rechargeable 230 mAh lithium-polymer battery, recording time of up to eight weeks, or replaceable Li-SOCI2 battery, operating time at least 2 years
- Coloured LED for status indication
- MSR175 software package with Dashboard software for easy start-up of the data logger, MSR ReportGenerator for automatic report generation and MSR ShockViewer for detailed analysis of shock events
Specifications
- 3-axis-acceleration range: +/- 15 g and +/- 200 g (-20 to +65 C)
- Accuracy (+/- 15 g sensor): +/- 0,15 g (05 g, +25 C) +/- 0,3 g (515 g, +25 C)
- Accuracy (+/- 200 g sensor): +/- 2 g (015 g, +25 C) +/- 5 g (15100 g, +25 C)
- Measurement/Storage rate: 1600/s (+/- 15 %); 3200/s (+/- 15 %)
- Temperature range and sampling time: -20 to +65 C (+/- 0,5 C (-10 to +65 C) measured every 10 minutes
- Humidity range and sampling time: 0 to 100 % rel. humidity (-20 to +65 C); +/- 2 % rel. humidity (1085 %, 0+40 C) / +/- 4 % rel. humidity (8595 %, 0+40 C) measured every 10 minutes
- Air pressure range: 02000 mbar absolute. +/- 2.5 mbar (7501100 mbar absolute, +25C) measured every 10 minutes
- Light range: 083000 lx. max. sensitivity at 550 nm measured every 10 minutes
- Memory capacity: Over 2,000,000 measurement values, 1000+ shock measurements
- Medium: Air
- Colour: Amber
- Key: Start measurement/retrieve status.
- Power supply: Replaceable Li-SOCI2 battery (3.6 V, 7700 mAh), battery operating time 2 years at least.