Features:
- Accurate & Reliable: Proven Temprecord performance
- 8K non-volatile memory
- Calibrated temperature accuracy is 0.2 C/0.35 F (Logger Case temperature range is -50 C to +60 C or -58 F to +140 F)
- 3-Point Calibration built into logger: No need for corrections or complex calculations to be applied to downloaded data and avoids human data entry errors, providing data integrity and peace of mind.
- Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standards
- Temperature Units: C or F
- Display Resolution: 0.01 C or 0.01 F
- Fully welded food grade plastic case: FDA approved and recyclable
- Case protection rating: waterproof to IP67 or NEMA 6
- Includes tefflon probe and 1m cable
- Requires the Temprecord SR2 Reader Interface. Sold separately, select under the related accessories tab
Software:
The Free software automatically calculates: MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli). It allows for hi-speed downloads, compatible with serial RS-232 or USB connectivity and is compatible with Windows XP, Vista & Windows 7. Compliance made easy with automated PDF report generation. Use speed-buttons from TRW software to:
- Save as *.TR and/or *.PDF files
- Export to MS Excel: part or all samples
- Email
- Print
Save time with Auto Mode (for batch programming):
- Start/Stop/Status display
- Download/read recorded data
- Save downloaded file as *.TR or *.PDF
- Print file
- Email file
- Reuse logger
Specifications
- Memory: 8K Non-volatile
- Sample Capacity: Approx. 7,935 samples minimum
- Sample Period: Programmable between 2 seconds and 36 hours in 2 second increments
- Start Delay Programmable between 10 seconds and 36 hours
- Start and Stop Logger Button (if enabled), Palm PDA/Reader, TRW Software/Reader
- Recording Duration: 4.4 hours to 2 years
- Operating Temperature Range of Case: -50 C to +60 C, -58 F to +140 F
- Operating Temperature Range of Data Logger: -50 C to +60 C, -58 F to +140 F
- Operating Temperature Range with STANDARD Temperature Probe: -80 C to +110 C, -112 F to +230 F
- Temperature accuracy (case): 0.2 C/0.35 F over the range -20 C/ -4 F to +50 C /+122 F else 0.5 C at 0.9 F
- Temperature accuracy (with probe): 0.2 C/0.35 F over the range -40 C/ -40 F to +50 C /+122 F else 0.5 C at 0.9 F
- Display Resolution: 0.01 C or 0.01 F
- Within Limits Indicator: One flash from Green LED Indicator every 10 seconds
- Out of Limits Indicator: One flash from Red LED Indicator every 10 seconds
- Battery Type: Lithium Thionyl Chloride (3.6V)
- Dimensions: 129 x 73.5 x 14mm or 51/8 x 27/8 x 5/8 inches
- Weight: 83g or 2.92oz
- Case Colour: Blue
- Case and Protection Rating: IP67 or NEMA 6. Fully welded FDA approved food grade casing
- Warranty: Period 12 months on data logger from date of purchase 2 years on battery