pH Electrode with Clogging Prevention System (CPS) and BNC Connector - IC-HI1048B

ORDER ME IN
Product code: IC-HI1048B

Backorder Now, once ordered your item will dispatch before the 20th of May 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).

The HI1048B is a glass body, refillable, sleeve junction pH electrode with a BNC connector. This electrode features a double junction reference, Hanna’s Clogging Prevention System (CPS) technology and spherical glass sensing bulb made with general purpose glass.
 
  • The CPS technology makes this probe ideal for wine, juice or other samples with solids as they contain substances that can clog other types of probes.
  • Has a spherical tip that provides a larger area for contact for faster and more stable readings.
  • Refillable Electrode (3.5M KCl).
Regular price $465.10 AUD + GST
$511.62 AUD Inc. GST
General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25 C and is suited for measuring pH of samples that are at ambient temperatures. The HI1048B is suitable to use with samples that measure from 0 to 80 C.
The spherical shaped tip design allows for a wide area of contact with the measured sample. This permits a faster electrode response with a higher degree of stability.
Clogging Prevention System (CPS) technology is an innovation in for the improvement of pH measurements in samples that have a high solids content. Conventional pH electrodes use ceramic junctions that can clog quickly when used in samples that have a high solids content such as wine must or juice. When the junction is clogged, the electrode does not function. CPS technology utilizes the porousness of ground glass coupled with a PTFE sleeve to prevent clogging of the junction. The ground glass allows proper flow of the liquid, while the PTFE sleeve repels solids. As a result, pH electrodes with CPS technology take up to 20 times longer to be fouled as compared to conventional electrodes.
A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or for samples that contains sulfides that can cause the silver to precipitates and clog the junction. Clogging of the junction will result in drifty and erratic readings.
The HI1048B is a refillable probe. Since it is a double junction pH electrode, the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode fill solutions. The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allow for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.

Specifications

Measurement Range
pH
Reference Cell Type
double, Ag/AgCl
Junction Type/Flow Rate
open, CPS technology
Refill Electrolyte
3.5M KCl
Body Material
glass
Tip / Shape
dome (dia
Matching Pin
no
Max. Pressure
0.1 bar
Temperature Operating Range
0 to 80C (32 to 176F) - GP
Body Length/Overall Length
120 mm / 175.5 mm
Temperature Sensor
no
Outer Diameter
12 mm
Cable
coaxial; 1 m (3.3)
Connector Type
BNC
Amplifier
no
Recommended Use
juice, must, wine

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au