SONUS Legislation Starter Pack - IC-NK006
Backorder Now, once ordered your item will dispatch before the 16th of May 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).
$4,278.56 AUD Inc. GST




The Legislation starter pack gives you the chance to begin the work in adhering to the Control of Noise at Work Regulations 2005 and make regular checks on noise levels in your workplace.
The kit contains a GA216I Integrating Sound Level Meter for noise level checks, GA257B Industrial Dosemeter to monitor employee personal exposure to noise levels and a GA601 single level calibrator to check the sound meter and dosemeter before and after measuring. The new Control of Noise at Work Regulations 2005 require all employers to reduce or prevent the risks to health and safety from noise exposure at work.
Noise levels must be monitored in all workplaces where there is a potential to exceed the levels set in the Regulations and steps taken to protect employees from hearing loss due to excessive noise. Features: - Area noise mapping of Leq - Simple dosimetry with predictive results - Instant calibration with Easycal - Tough and reliable pocket sized instruments
GA116I - Integrating Sound & Lepd meter
The Castle SONUS is a new range of pocket meters designed for ease of use with the power the cover the work you need, from Noise at Work measurements to Environmental monitoring. The SONUS sound level meters are split into a range of meters to suit specific needs.
The Integrating SONUS, GA116I offers different measurement parameters including Lep'd and Dose enabling the sound meter to also double as a dosemeter. The meter is ideal for Industrial Safety Officers and Safety Managers and can be used for Health and Safety at Work Act; Noise Regulations 1989. The GA116I gives all the required information for Noise at Work risk assessments.
Applicable Standards:
IEC 61672-1:2002 Class 1 Group X
BS EN 61672-1:2003 Class 1 Group X
IEC 61252:1993
BS EN 61252-1997 + A1:2001
Specifications
Microphone and Preamplifier:
Custom pre-amplifier design
Typical actuator to free-field correction factor (based on 500Hz=0) is shown below
20Hz: 0 1kHz: 0
25Hz: 0 1.25kHz: +0.2
31.5Hz: 0 1.6kHz: +0.4
40Hz: 0 2kHz: +0.5
50Hz: 0 2.5kHz: +1.0
63Hz: 0 3.15kHz: +1.2
80Hz: 0 4kHz: +1.5
500Hz: 0 5kHz: +2.0
630Hz: 0 6.3kHz: +2.5
800Hz: 0 8kHz: +3.8
Display:
Back-lit LCD panel (8x1 Characters)
Alpha-Numeric display for measured results
Level Range:
B and I Models:
Measuring Range: 35-140
Linear Operating Range (IEC61672-1): 65dB
3 Measurement Ranges (IEC61672-1): 35-100, 55-120 (Reference Range), 75-140
Noise Floor:
Typical: 'A' Weighting 23 dB(A) rms,
'C' Weighting 24 dB(C) rms, 'Z Weighting 25 dB(Z) rms (L Only)
Frequency Weighting:
'A' and 'C' to IEC 61672-1:2002 and IEC 60651:1979+A1+A2
1672-1:2002
Combinations of A, A&C simultaneous or A&Z simultaneous available for Leq, Lmax and Pmax
Frequency Range:
20 Hz - 8 kHz (including microphone)
1 Hz - 20 kHz (electrical characteristics)
DOSE Calculations:
Exchange rate: 3dB, 4dB or 5dB
Criterion Level: 75dB, 80dB, 85dB or 90dB
Threshold Level: -5dB, -10dB or OFF
Instrument Response:
Simultaneous Peak and RMS
Calibration:
Software controlled 91.0 to 120.0 dB (1kHz) in 0.1 dB steps
Memory:
2100 Data Intervals Maximum
Power Requirements:
Batteries: 1 x 6LR61 (size PP3), Life: >12 hours (alkaline batteries, continuous operation)
Size and Weight:
Dimensions: 60mm (width) x 35mm (depth excluding pocket clip) x 135mm (height without microphone) or 210mm (height with microphone)
Weight: 220gms (including battery)
Operating Temperature:
Operating Range: -10 to + 50C
Humidity:
Effect: < 0.5dB from 25% to 90% RH
Vibration:
No effect on instrument
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours