testo 312-4 - Differential pressure measuring instrument up to 200 hPa

ORDER ME IN
Product code: IC-0632-0327

Backorder Now, once ordered your item will dispatch before the 10th of May 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).

Differential pressure gauge testo 312-4.
Regular price $1,838.00 AUD + GST
$2,021.80 AUD Inc. GST

A measuring instrument for carrying out all necessary tests on gas heaters and pipes as well as water pipes. Inherently safe thanks to the use of C-Flex hoses with high impermeability. Legally compliant measurement procedure for pre-test, main test and leakage quantity measurement on gas pipes. Recording of measurement values over a defined period (e.g. 24 h) and data transfer and analysis on PC software incl. graphic presentation.

Features:
- Tightness testing and load testing on gas pipes
- Serviceability testing with air by pressure drop on gas pipes
- Pressure testing on drinking water and waste water pipes using air
- Automatic recording of measuring values over several hours

Specifications

Temperature - Type K TC:
- Measuring range: dependent on probe type used
- Accuracy: +/- 0 0.7 F (-148 to 392 F)* / +/- 0.4 C (-100 to +200 C)*/ +/- 2 F (Remaining Range)* / +/- 1 C (Remaining Range)*
- Resolution: 0.01 F t1 / 0.01 C
Differential pressure (internal sensor):
- Measuring range: 0 to 80 InH?O / 0 to 200 hPa
- Accuracy: +/- 0.01 InH2O (0 to +1 InH?O) / +/- 0.03 hPa (0 to +3 hPa)/+/- 1.5 % of mv (+1.2 to +16 InH?O) / +/- 1.5 % of mv (+3.1 to +40 hPa)/ +/- 1 InH2O or +/- 1 % of full-scale value (16 to +80 InH?O) / +/- 2 hPa or +/- 1 % of fsv (41 to +200 hPa)
- Resolution: 0.01 InH?O / 0.01 hPa
Pressure measurement (external probe):
- Measuring range: 0 to 363 psi / 0 to 25 bar
- Accuracy: +/- 0.6 % of full-scale value (0 to 145 psi) / +/- 0.6 % of fsv (0 to 10 bar)/ +/- 0.6 % of full-scale value (>145 to 363 psi) / +/- 0.6 % of fsv (>10 to 25 bar)
- Resolution: 4 InH2O / 10 hPa
General technical data:
- Dimensions: 9 x 3 x 2 in. / 219 x 68 x 50 mm
- Interface printer: Infrared interface
- Data transfer: RS232
- PC software: Easyheat
- Memory: 25,000 measuring values
- Weight: 21 oz. / 600 g
*Accuracy information applies only to instrument without probes connected


Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au