Features:
- User-friendly: All measurements are shown simultaneously on the 80 character display. There is no need to change modes to check any of your vital data. The user-friendly menu system guides the operator through all operations such as calibration, setup etc. Full text help and error messages are provided along the way.
- Waterproof: The 90 series is designed for rugged field applications in wet environments. The case, keypad and connectors are rated to IP65.
- Good Laboratory Practices: To comply with GLP guidelines, the date, time and results of the last calibration are stored in memory, along with the unit's serial number. This data can be displayed or sent directly to the RS232 port. Warning of failed calibration is provided. All readings stored in memory are stamped with the date and time.
- Notepad Function: A standard feature of the 90 series is the Notepad function. Up to 8100 sets of readings (depending on model) can be recorded for later review. These can be downloaded to a printer or computer via the RS232 port. For added functionality, the user is able to enter up to two additional items to be tagged on to the reading. Many operators use this function as a pond or site identifier, depth or readings from other instruments.
- Datalogging: Automatic datalogging provides the capability to automatically record up to 8100 sets of readings (depending on model) at user-set intervals. The unit remains dormant between readings and only wakes up whenever a reading is due. Battery life is considerably improved with this facility.
- RS232 Serial Port Interface: All recorded data can be downloaded directly to a Printer or Computer with the standard RS232 port (cable sold separately). With the WinTPS communication software, many instrument functions can be controlled from the computer. This makes the units ideal for remote monitoring.
The 90 Series is proudly designed and manufactured in Australia. Our aim is to provide you with the best quality, service and value for money. The TPS Quality System has been certified in accordance with the AS/NZS ISO 9001 standard. Since 1968, TPS has built a reputation for excellent backup service that is second to none.
Specifications
pH:
- Range: 0 to 14.00 pH
- Resolution: 0.01 pH
- Accuracy: +/-0.01pH
- Impedance: >3 x 1012 Ohms
- Asymmetry: -1.00 to +1.00 pH
- Range: 85 to 105%
- Temperature Compensation : Automatic, -5 to 100 C
- Calibration : 2 Point automatic
- pH Buffers : Auto recognition of pH4.01, pH6.86, pH7.00, pH9.18 and pH10.01. Other buffers can be keyed in at calibration.
mV:
- Range: 0 to +/-1999 mV
- Resolution: 1 mV
- Accuracy: +/-1 mV
Conductivity:
- Range: 0 to 20.00 uS/cm; 0 to 200.0 uS/cm; 0 to 2000 uS/cm; 0 to 20.00 mS/cm
- Resolution: 0.05% of full scale of selected range.
- Accuracy: 0.5% of full scale of selected range at 25 C
- Temperature Compensation: All readings automatically normalized to 25oC at -2.2%/ C.
- Zero Calibration : Automatic in air.
- Calibration : Automatic to user- defined standard
Turbidity:
- Ranges: 0.1 to 200.0 NTU/ 0 to 2000 NTU (Ranges subject to sensor performance)
- Resolution: 0.1 NTU/1 NTU
- Accuracy: +/-1 NTU
- Linearity: 3%
- Temperature Coefficient : -0.3%/C, 0 to 40C
- Zero Calibration: Automatic in distilled water.
- Calibration: Automatic to user- defined standard.
TDS:
- Range: 0 to 10.00 ppM; 0 to 100.0 ppM; 0 to 1000 ppM; 0 to 10.00 ppK
- Resolution : 0.1% of full scale of selected range.
- Accuracy : 0.5% of full scale of selected range
- Temperature Compensation : All readings automatically normalized to 25 C at -2.2%/C.
- Zero Calibration : Automatic in air.
- Calibration : Automatic to user- defined Conductivity standard.
Salinity:
- Range: 0 to 1.19 % 0 to 11.9 PSU
- Resolution : 0.01 % or 0.1 PSU
- Accuracy : 0.5% of full scale of selected range at 25 C.
- Temperature Compensation : All readings automatically normalized to 25 C at -2.2%/ C.
- Zero Calibration: Automatic in air.
- Calibration : Automatic to user- defined Conductivity standard.
Dissolved oxygen:
- Ranges: 0 to 32.00 ppM (mg/L); 0 to 320.0 %Saturation; 0 to 66.0 %Gaseous
- Resolution: 0.01 ppM (mg/L); 0.1 %Saturation; 0.1 %Gaseous
- Accuracy : 0.02 ppM (mg/L); 0.3 %Saturation; 0.1 %Gaseous
- Temperature Compensation : Automatic for solubility (ppM only) and membrane permeability.
- Calibration : Automatic at less than 5%.
- Calibration : Automatic in air.
- Range : -10.0 to 110.0 C (Cond. sensor limit 60 C)
- Resolution : 0.1 C
- Accuracy : +/-0.2 C
- Compensation : Automatic, -5 to 100oC
- Calibration : 2 Point automatic
- pH Buffers : Auto recognition of pH4.01, pH6.86, pH7.00, pH9.18 and pH10.01.
- Other buffers can be keyed in at calibration.
General:
- Good Laboratory Practices: Date, time and value of last calibration for each parameter are stored. This information can be recalled or sent to the RS232 port at any time.
- Warning of failed calibration is provided: All readings stored in memory are stamped with the date and time.
- Datalogging: 7200 readings (5900 with extra data input active)
- Extra Data Input 2: Extra items of data can be input when using the Notepad function. Each item can be a maximum of 4 characters, including a decimal point. Extra Data items are labelled A and B
- Automatic Logging: Automatically log from 1 to 288 readings per day; Automatically log readings at a preset interval for a preset duration
- RS232 Serial Port Output: 8 Bits, No Parity, 1 Stop Bit, XON/OFF Protocol. 300, 9600 & 19200 baud available.
- Display: 2 line x 40 Character alphanumeric LCD shows all readings simultaneously.
- Keypad: 5 Function keys, Menu key, 14 data entry keys, OFF, ON.
- Dimensions: 230 x 140 x 100 mm