PC 2000 Features:
-2.000 to 20.000 pH range
- 0.1, 0.01, & 0.001 pH resolutions
- USA, NIST, NIST2, DIN, and Custom pH buffer groups
- Up to 6 pH calibration points
- Offset, segment and average slopes data after pH calibration
- Adjustable calibration alarm up to 90 days
- -2000.0 to +2000.0 mV range with ORP calibration option
- 0.000 ug/L to 9999 g/L ion range with 3 selectable units
- Up to 5 user-defined ion calibration points
- Segment and average slopes data after ion calibration
- Up to 2.000 S/cm conductivity range
- Adjustable reference temperature: 15 to 30 C
- Adjustable temperature coefficient: 0.00 to 10.00 % per C
- Accepts 0.0700 to 13.000 cell constant
- Allows auto and manual conductivity calibrations
- Up to 5 conductivity calibration points
- Auto ranging S/cm and S/m conductivity units
- 0.01 mg/L to 100 g/L TDS range
- Pre-programmed TDS curves: Linear (0.40 to 1.00 TDS factor), EN27888, 442, & NaCl
- 0.0 to 100.0 ppt and 0.00 to 10.00 % salinity ranges
- Pre-programmed salinity curves: NaCl and seawater
- -30.0 to 130.0 C temperature range with calibration option
- Auto stable, auto hold, and real time measurement modes
- Electrode status, temperature, and reading stability indicators viewable at a glance
- Large memory accepting up to 2000 data sets with date/time stamp
- Auto data log function with adjustable time interval
- Real time clock facilitating time-dependent functions
- Adjustable auto shut-off time up to 30 mins.
- Password protected set-up mode for security
- Software upgrade capability
- PC communication via USB cable and complimentary data acquisition software
- Printer communication via RS232 cable
- 5 inch Digital, custom LCD display with backlight
- Sleek design with easy-to-use interface and audible key sound feedback
- Small meter footprint with adjustable, integrated electrode stand
PC 2000 Specifications:
pH:
-Range: -2.000 to 20.000 pH
- Resolution: 0.1 / 0.01 / 0.001 pH
- Accuracy: +/- 0.003 pH
- pH Buffer Groups USA, NIST, NIST2, DIN, Custom Calibration Points Up to 5 (USA, NIST, NIST2) / Up to 6 (DIN, Custom)
ORP:
- Range: +/- 2000.0 mV
- Resolution: 0.1 mV
- Accuracy: +/- 0.2 mV
- Calibration Option: Yes (Up to +/- 200 mV)
Ion:
- Range: 0.000 ug/L to 9999 g/L
- Units: ug/L to mg/L to g/L, ppm to ppt, mmol/L to mol/L
- Resolution: 4 Significant digits
- Accuracy: +/- 0.3% full scale or +/- 0.2 mV, whichever is higher
- Calibration: Points Up to 5
Conductivity:
- Range: 0.000 to 1.999 S/cm (k = 0.1); 2.00 to 19.99 S/cm (k = 0.1, 1); 20.0 to 199.9 S/cm (k = 0.1, 1, 10); 200 to 1999 S/cm (k = 0.1, 1, 10); 2.00 to 19.99 mS/cm (k = 0.1, 1, 10); 20.0 to 199.9 mS/cm (k = 1, 10); 0.200 to 2.000 S/cm (k = 10)
- Units: Auto ranging S/cm, S/m (S to mS)
- Resolution: 0.05% full scale
- Accuracy: +/- 0.6% full scale; +/- 1.5% full scale greater than 18.0 mS/cm
- Reference Temperature: 15.0 to 30.0 C (adjustable)
- Temperature Coefficient: 0.00 to 10.00 % per C (adjustable)
- Cell Constants: 0.0700 to 13.000 (adjustable)
- Calibration Points: Up to 4 (Auto) / Up to 5 (Manual)
Resistivity:
- Range: 0.000 ohm centimeter to 20.0 million ohms
- Resolution: 0.5% full scale
- Accuracy: +/- 0.6% full scale; +/- 1.5% full scale
TDS:
- Range: 0.01 to 9.99 mg/L (ppm); 10.0 to 99.9 mg/L (ppm); 100 to 999 mg/L (ppm); 1.00 to 9.99 g/L (ppt); 10.0 to 100 g/L (ppt)
- Resolution: 0.01, 0.1, 1 mg/L to g/L (ppm to ppt)
- Accuracy: +/- 0.1% full scale
- TDS Curves: EN27888, 442, NaCl, Linear (0.40 to 1.00)
Salinity:
- Range: 0.0 to 100.0 ppt / 0.00 to 10.00 %
- Resolution: 0.1 ppt / 0.01%
- Accuracy: +/- 0.2% full scale
- Salinity Curves: NaCl / Seawater
- Calibration Option: Yes
Temperature:
- Range: -30.0 to 130.0 C
- Resolution: 0.1 C
- Accuracy: +/- 0.5 C
- Calibration Option: Yes ( 10.0 C / 18.0 F range in 0.1 C increments)
General:
- Memory: 2000
- Auto Data Log: Yes
- Real-time Clock: Yes
- Date & Time Stamp: Yes
- Measurement Modes: Auto Stable / Auto Hold / Real Time
- Offset & Slope Display: Yes (Segment & Average Slopes)
- Calibration Alarm: Yes (Programmable: up to 90 days)
- Auto Shut-Off: Yes (Programmable: up to 30 mins.)
- Electrode Status: On screen display
- Diagnostics: Yes
- Password Setting: Yes
- Software Upgrade: Yes
- PC / Printer Communication: Phono jack (USB / RS232C)
- Meter Inputs: 2x BNC, 2x phono (ATC), DC sockets
- Display: 5 inch Custom LCD with backlight and 320 segments
- Power Requirement: AC adaptor 100 to 240V, 50 to 60Hz
- Dimensions & Weight: 155(L) x 150(W) x 67(H) mm, 770g