FieldLogger Data Logger 512k Memory with HMI 24VDC/AC
Product code: IC-NOD-004
3+$1,970.8865ex. GST
5+$1,950.8775ex. GST
10+$1,930.8685ex. GST
The new FieldLogger from Novus is a versatile, powerful and yet cost effective data logger handling analog, digital and other types of variables with high resolution and speed. It features high performance and high speed connectivity and yet is easy to configure and operate.
FieldLogger has one USB interface to be connected to a computer (for configuration, monitoring and data download) and another USB port for plugging a flash driver for data retrieval. The 512k logging basic memory is used to store data and it can be greatly expanded with an SD card.
This version comes with a colour HMI attached to the front of the logger for display of alarms, graphs and configuration of the logger. A user friendly configurator software can be accessed by Ethernet, USB or RS-485 and also provides means for on-line monitoring, logged data downloading and exporting to spread sheets and other formats.
To make life easier for you, all data generated on the Fieldlogger can be published on the NOVUS Cloud platform free of charge, which allows access anytime and anywhere, besides providing efficient and reliable storage.
Features
- Ethernet interface with a lot of services available:
1. Sends alarm warning e-mails (SMTP)
2. Provides web pages with channels and status information (HTTP)
3. Allows logged data download via FTP (client and server)
4. Accesses status and channels values through network management software (SNMP and traps)
5. Allows Modbus communication by ethernet interface (Modbus TCP)
- USB-device interface for configuring, monitoring and download
- USB-host interface for logged data retrieval through a USB flash drive
- Up to 32 configurable alarms. Alarm actions can include:
1. Activating relays
2. Activating digital outputs
3. E-mails sending to multiple receivers
4. Sending SNMP traps
5. Starting and/or stopping loggings
- Optional detachable human-machine interface
- Data Loggings:
1. Up to 100 channels can be logged at a configurable rate
2. Data download through the configuration software or through the freely distributed download DLL
Specifications:
- Power supply: 24 VDC/VAC
- Output: 24 VDC for powering up to eight 4 to 20 mA transmitters
- Universal analog input channels: 8 (Thermocouples,V, mV, mA, Pt100 and Pt1000)
- Accuracy (Thermocouples J, K, T, E and N): 0.2 % of the span +/- 1 C
- Accuracy (Thermocouples R, S and B): 0.2 % of the span +/- 3 C
- Accuracy (Pt100, Pt1000): 0 to 20 mA, 4 to 20 mA, 0 to 20 mV, 0 to 50 mV, 0 to 60 mV, - 20 to 20 mV, 0 to 5 V and 0 to 10 V: 0.15 % of the span.
- Digital I/Os: 8 (individually configured as input or output)
- Digital inputs: Logic level 0: from 0 to 0.8 Vdc, Logic level 1: from 2 to 30 Vdc, Maximum input voltage: 30 Vdc, Input current at 30 Vdc (typical):
3 mA
- Digital output: Maximum output voltage: 30 Vdc/Maximum output current: 200 mA
- Relay output: 2 (NO, NC and common)
- Reading and logging rates: Up to 1000/second
- A/D conversion resolution: 24 bit
- Memory: 512K
- Alarm: Up to 32 configurable alarms.
- Maximum TCP simultaneous connections: 10
- Maximum UDP simultaneous connections: 10
- Communication interface: RS485 interface (Modbus master or slave)
- When acting as a master, can read up to 64 registers from other slaves
- Registers read can be used in logging, alarms or mathematical operations
- Up to 128 virtual channels:
- Basic mathematical functions to be applied on other channels: sum, subtraction, multiplication, division, logic (AND, OR and exclusive OR), square
root and power
- Protection: IP20
- Operating temperature: 0 to 50 C
- Relative humidity: 80 % up to 30 C (For temperatures higher than 30 C, decrease 3% for C )
File | Type | Size | Created At |
---|---|---|---|
NOD-004..ual.pdf | 6.06 MB | 27/1/2021, 2:22 PM | |
NOD-004..ide.pdf | 280.10 KB | 27/1/2021, 2:22 PM |
Delivery Details
FREE Startrack Premium Air Express in Australia - Non-Bulky Items |
---|
Free Delivery in Australia for orders over $100. Overnight delivery to most capital cities and surrounding areas (2 to 5 day delivery outside these locations). - Most articles delivered next business day when using this service. Next–business-day delivery is only available between capital cities (excluding Darwin, and for Perth between CBDs only) and some major centres. - Shipped from Instrument Choice on South Australian business days
Free Delivery in Australia for orders over $100
|
For alternate delivery options and international shipping, click here.
FREE Express Road Courier (NO PO Box, Authority to leave) - Bulky Items |
---|
Free Delivery in Australia for orders over $100. Typically 2 to 5 working day delivery time to capital cities (Up to 2 weeks outside these locations.)
- Products are shown as bulky items on their product pages - Delivered only on business days at your location, delivery unavailable on weekends and public holidays
- Shipped from Instrument Choice on South Australian working days
This service does not deliver to Post Office Boxes
Free Delivery in Australia for orders over $100
|
For alternate delivery options and international shipping, click here.
Why Instrument Choice?
#1. SUPER-RESPONSIVE CUSTOMER SERVICE
#2. SPECIAL ADVICE FROM SCIENTISTS
#3. Easy Shopping
#4. Free Express Shipping
Why pay for shipping when Instrument Choice has negotiated such amazing freight rates for Australia and New Zealand? Overnight shipping is available to capital cities for 93% of stocked items, the rest still travel by express road to get to you quickly.
Get details about our super-fast and secure shipping options here